zlacker

[parent] [thread] 5 comments
1. Neywin+(OP)[view] [source] 2026-02-01 22:58:45
So just to confirm, the actual cause for the controls not working is still unknown to the reader but the reason the measurements didn't make sense was swapped labels?
replies(1): >>sberen+7o
2. sberen+7o[view] [source] 2026-02-02 02:34:35
>>Neywin+(OP)
The controls weren't working because we had wired them up according to the labels which were wrong (which is also why the measurements didn't make sense to us).
replies(1): >>Neywin+Vo
◧◩
3. Neywin+Vo[view] [source] [discussion] 2026-02-02 02:43:28
>>sberen+7o
Ah. A lesson from somebody who's built hardware that I'm sure you've now learned: make sure connectors can't plug into eachother unless they're supposed to. Even if they're different connectors, different keying, whatever, sometimes they can still be forced together.
replies(3): >>abdull+dl7 >>sowbug+Cp7 >>tuetuo+gI7
◧◩◪
4. abdull+dl7[view] [source] [discussion] 2026-02-03 22:47:24
>>Neywin+Vo
I built a lot of Ikea last month. And I was just marveling how cleverly designed everything was so that it was quite difficult to put two wrong pieces together. Mostly, the only warnings in the manuals were to rotate a piece correctly.
◧◩◪
5. sowbug+Cp7[view] [source] [discussion] 2026-02-03 23:13:08
>>Neywin+Vo
This is good advice for robust design, but I swear, 9 times out of 10, you will be the one who keys it the wrong way during CAD layout.
◧◩◪
6. tuetuo+gI7[view] [source] [discussion] 2026-02-04 01:00:50
>>Neywin+Vo
I've seen datacenter techs successfully force an SFP optic in an RJ45 port. So yeah, the shape needs to be very different.